1-866-225-6937 info@canadablower.com

Northern Industrial Co. engineers various models and sizes of Industrial Make-Up Air Systems for larger industrial plants ventilation needs.

Negative Air Pressure in industrial manufacturing facilities can create problems such as:

– Exhaust fans losing performance, as the building pressure becomes negative.

– Pilot light outages and exhaust system failure on natural draft gas equipment.

– Cold air drafts and infiltration of dirt and contamination from outside.

– Difficulty opening or closing exterior doors.

Headaches and nausea among personnel due to inadequate ventilation. In temperate climates or during mild weather, moderate amounts of make-up air can be supplied by simply opening windows or overhead doors. However, this is usually not the case in industrial and commercial facilities. Forced ventilation Make-up air is required.

Direct Gas-Fired Make-up Air Units supply tempered and filtered air to the indoor environment. In summer, a direct-fired unit may be used as an air handler, with the heater disabled. By adding a DX or evaporative cooling section to the unit, it may be used to supply conditioned air year round.

Make-Up Air Applications:

There are three general applications for Make-Up Air Units:

– Direct Compensating Ventilation

– General Area Ventilation

– Door Heating

Direct Compensating Ventilation.

Conditioned Air is Delivered to the Immediate Vicinity of Exhaust. This is the case for welding fume extractors, stovetop exhaust hoods, paint booths, or similar applications.

General Area Ventilation.

Conditioned Air Blankets Entire Area of Building to Compensate for Many Exhausts. Introduced in Cleanest Part of Building – Flows to Negative Pressure Areas – Picks up Dust, Vapors, and Odors en route.

Door Heaters

Heated Air is introduced at open doors to warm incoming air or compensate for loss. Heater may also be used as part of an “air door” system.

Typical Industrial Uses:

* Plating Tanks

* Paint Spray Booths

* Welding Operations

* Chemical Exhaust

* Degreasing

* Factory Ventilation

* Plastic Molding

* Foundry Works

* Grinding & Buffing Operations

Typical Commercial Uses:

* Warehouses

* Kitchens

* Entryways

* Gymnasiums

* Pools

* Exposition Buildings

* Garages

While there are no facts and figures to show how many buildings in the United States provide the correct amount of makeup air, it can be surmised that there are probably a great many that do not have sufficient makeup air. And there’s no one solution that is available for every building. Each building must be analyzed with a careful air balance calculation and evaluated based on the diversity of sources of exhaust air and infiltration.

Make-Up Air Volume Requirements:

The recommended method for calculating Make-up Air Volume is to determine the total CFM capacity of exhaust fans, blowers, stacks, etc. in the building and add 10%. This will create a positive pressure in the building.

When information is not available, the following estimates may be used to determine approximate requirements:

– Paint / Spray Booth: 100 to 200 CFM per sq. ft. of face opening.

– Oven Exhaust: One air change per minute.

– Fume Exhaust: Area of Pipe (in square feet) x velocity (3,000 feet/min average) = CFM.

– Roof Ventilator: same as Fume Exhaust.

– Canopy Hoods: 100 to 300 CFM per square foot of hood open area.

– Furnace Combustion Air: Minimum CFM = BTU/hr rating / 6,000.

– Drying, Baking, Curing Ovens: 100 CFM per square foot of booth cross section.

– Pickling or Cleaning Tanks: 150 CFM per square foot of door opening or 200 CFM per square foot of hood face opening.

Additional information can be found at the Northern Industrial company web site http://www.northernindustrialsupplycompany.com/

Tags: Axial Ventilator, Axial Roof Ventilators, Blower Fan Suppliers, Centrifugal Blower Fan, Centrifugal industrial Fan, Centrifugal Wall Fans, High Temperature Blower, Industrial Axial Inline Direct Drive Fans, Industrial Blower Manufacturer, Industrial Blowers Suppliers, Industrial Centrifugal Blower, Industrial Fans and Blowers, Industrial Fans Canada, Industrial Pressure Blower, Large Industrial Fan, Roof Supply Fans, Single Stage Pressure Blower, Wall Supply Fans, Blower, Blower Fan, Centrifugal Roof Exhausters, Inline Belt Drive Fans, Inline Exhaust Fans, Material Handling Fans, Roof Exhaust Fans, Ventilator, Wall Exhaust Fans, industrial axial ventilator, axial ventilator fan, axial ventilator blower, axial ventilator blower fan, roof axial ventilator, industrial centrifugal blower fan, centrifugal blower fan, high pressure temperature fan, large industrial blower fan, temperature blower, pressure blower, blower high temperature, blower high pressure, centrifugal blower industrial fan, blower centrifugal industrial, large fan industrial, high temperature, high pressure, wall fans, roof fans, exhaust fans, exhaust fans for walls, exhaust fans for roof, fans material handling, industrial material handling fans, inline exhaust, fans inline exhaust, fans wall exhaust, fans roof exhaust, supply fans for walls, supply fans for roofs, blower low pressure, low pressure blower